MPF multiple pumps can be assembled from our stock and are identical in construction to the HP multiple pumps.
currently can 7 Pumps from stock can be assembled.
HP11-2+1.2+1199-99-C
keine Artikelnummer gefunden
Explanation of the type designation
2
Anzahl Stufen
MPF11
Hesper Gear pump primary stage group 1
2
Fördervolumen Level 1= 2 cm³/Umdrehung max Dauerdruck 250 bar, max Spitzendruck 280 bar n =2900 U/min, p1 =100 bar, Q1 =5.16 l/min, P1 =1.27 kW, M1 =4.19 Nm
1
conical shaft 1:8, ø9,74, Key width 2,4
1
Drive flange according to EU standards ø25,4 (52x72x26,5 / 4xM6)
99
Level 1: Suction connection G3/8 und Pressure connection G3/8
C
Drehrichtung rechts
MPM111
Hesper Gear pump secondary stage group 1
1.2
Fördervolumen Level 2= 1.2 cm³/Umdrehung max Dauerdruck 250 bar, max Spitzendruck 280 bar n =2900 U/min, p2 =50 bar, Q2 =2.99 l/min, P2 =0.4 kW, M2 =1.33 Nm
99
Level 2: Suction connection G3/8 und Pressure connection G3/8
Speed range 1200 to 3500 RPM
Total drive power =1.67 kW
Total length without screws = 18+37.4+17+17+34.5+18 = 141.9mm